• Services
    • Asses
      • Compromise Assessment
      • APT Assessment
      • Penetration Testing
      • Secure Architecture Design & Review
      • Red Team Assessment
      • Purple Team Assessment
      • Social Engineering
      • Source Code Review
    • Transform
      • SOC Consultancy
      •     SOC Maturity Assessment
      •     SOC Model Evaluation
      •     SOC Gap Analysis
      •     SIEM Gap Analysis
      •     SIEM Optimization
      •     SOC Content Pack
    • Train
      • Security Awareness and Training
      • Tabletop Exercise
      • Simulated Cyber Attack Exercises
    • Respond
      • Incident Response
      • Incident Analysis
  • Managed Security
    • Managed Security Monitoring
      • Remote SOC
      • Onsite SOC
      • Hybrid SOC
    • Managed Security Services
      • Managed Detection and Response
      • Managed Endpoint Detection and Response
      • Managed Threat Intelligence
      • Managed Threat Hunting
      • Managed Risk-Based SOAR
      • Managed Penetration Testing
  • Solutions
  • Resources
    • Blog
    • Threat Advisory
  • Company
    • About Us
    • Careers
    • Contact
Rewterz Threat Alert- Flawed Ammyy RAT (aka FlawedAmmyy RAT) Malware – Threat Indicators
March 7, 2019
Rewterz Threat Advisory – Cisco Nexus 5600 / 6000 Series Switches NX-OS FCoE Denial of Service Vulnerability
March 7, 2019

Rewterz Threat Advisory – CVE-2019-6528 – Cross-site Scripting Vulnerability due to Improper Neutralization of Input

March 7, 2019

Severity

High

Analysis Summary

The vulnerability exists due to improper neutralization of input during web page generation process. The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.

Affected Vendors

PSI GridConnect GmbH

Affected Products

Telecontrol Gateway and Smart Telecontrol Unit family
IEC104 Security Proxy
Telecontrol Gateway 3G Versions 4.2.21
5.0.27
5.1.19
6.0.16 and prior;
Telecontrol Gateway XS-MU Versions 4.2.21
Telecontrol Gateway VM Versions 4.2.21
Smart Telecontrol Unit TCG Versions 5.0.27
6.0.16 and prior; and
IEC104 Security Proxy Version 2.2.10 and prior.

Remediation

A fix for the vulnerability is available in the following software releases:

  • 5.1.20,
  • 6.0.17, and
  • IEC104 Security Proxy Version 2.2.11

The following software releases are no longer supported:

  • 4.2.x, and
  • 5.0.x

PSI recommends deactivating the webserver via CLI since the web interface is not essential to the configuration of the device.

  • Services
    • Asses
      • Compromise Assessment
      • APT Assessment
      • Penetration Testing
      • Secure Architecture Design & Review
      • Red Team Assessment
      • Purple Team Assessment
      • Social Engineering
      • Source Code Review
    • Respond
      • Incident Response
      • Incident Analysis
  • Transform
    • SOC Consultancy
    •     SOC Maturity Assessment
    •     SOC Model Evaluation
    •     SOC Gap Analysis
    •     SIEM Gap Analysis
    •     SIEM Optimization
    •     SOC Content Pack
  • Train
    • Security Awareness and Training
    • Tabletop Exercise
    • Simulated Cyber Attack Exercises
  • Managed Security
    • Managed Security Monitoring
      • Remote SOC
      • Onsite SOC
      • Hybrid SOC
    • Managed Security Services
      • Managed Detection and Response
      • Managed Endpoint Detection and Response
      • Managed Threat Intelligence
      • Managed Threat Hunting
      • Managed Risk-Based SOAR
      • Managed Penetration Testing
  • Solutions
  • Resources
    • Blog
    • Threat Advisory
  • Company
    • About Us
    • Careers
    • Contact
COPYRIGHT © REWTERZ. ALL RIGHTS RESERVED.